Transcript
Vamos fazer este estudo de densidades:,,,,,,,,,,,,,,,
Densidade do concreto = d = Massa/volume = (1+m+a/c) / (1/dcim+m/dagreg+(a/c)/dagua),,,,,,,,,,,,,,,
,,,,,,,,,,,,,,,
Logo se resolvendo esta equação temos então que:,,,,,,,,,,,,,,,
m= [d/dcim+(a/c)*d/dagua-1-(a/c)] / (1-d/dagreg),,,,,,,,,,,,,,,
,,,,,,,,,,,,,,,
temos também as seguintes formulações:,,,,,,,,,,,,,,,
A%= (a/c) / (1+m),,,,,,,,,,,,,,,
C= 1000 / (1/dcim + m/dagreg + (a/c)),,,,,,,,,,,,,,,
,,,,,,,,,,,,,,,
,MANTENDO O MESMO a/c,,,,,,,,,,,,,,
QUADRO 1,,,QUADRO 2,,,,,,,,,,,,
densidades:,,,,densidades:,,,,,,,,,,,
cimento,3100,Kg/m3,,cimento,3100,Kg/m3,,,,,,,,,
mistura agregados,2700,Kg/m3,,mistura agregados,2700,Kg/m3,,,,,,,,,
água,1000,Kg/m3,,água,1000,Kg/m3,,,,,,,,,
concreto,2400,kg/m3,,concreto,2500,kg/m3,,,,,,,,,
,,,+100kgm3,,,,,,,,,,,,
cálculos:,,,,cálculos:,,,,,,,,,,,
a/c=,0.54,,,a/c=,0.54,,,,,,,,,,
m=, 4.77 ,,,m=, 8.32 ,,,,,,,,,,
,,,+3.55,,,,,,,,,,,,
A%=,9.36%,,,A%=,5.79%,,,,,,,,,,
,,,-3.57,,,,,,,,,,,,
C=, 380.00 ,Kg/m3,,C=, 253.00 ,Kg/m3,,,,,,,,,
,,,-127kgm3,,,,,,,,,,,,
,,,,,,,,,,,,,,,
Resistência prov.=, 36.44 ,Mpa,,Resistência prov.=, 36.44 ,Mpa,,,,,,,,,
,,,,,,,,,,,,,,,
,,,,,,,,,,,,,,,
"--Para se aumentar a densidade em 100kg/m3 e se mantendo o mesmo ""a/c"" teremos de diminuir o cimento",,,,,,,,,,,,,,,
"e aumentar ""m"". Houve uma queda de 127kg/m3 para se aumentar a densidade em 100kg/m3. ",,,,,,,,,,,,,,,
"--Com este aumento de ""m"" o teor de água materiais secos A% cai muito (3.57%).",,,,,,,,,,,,,,,
--Com a diminuição do teor de água materiais secos A% é necessário ter vibração muito energica,,,,,,,,,,,,,,,
"e com prensagem muito energica, tipico para concreto semi-seco, com máquinas de grandissimo porte.",,,,,,,,,,,,,,,
--A cura para este nivel de A% deve ser MUITO bem controlada (A% muito abaixo de 7%).,,,,,,,,,,,,,,,
,,,,,,,,,,,,,,,
,"MANTENDO O MESMO ""m"" ",,,,,,,,,,,,,,
QUADRO 1,,,QUADRO 3,,,,,,,,,,,,
densidades:,,,,densidades:,,,,,,,,,,,
cimento,3100,Kg/m3,,cimento,3100,Kg/m3,,,,,,,,,
mistura agregados,2700,Kg/m3,,mistura agregados,2700,Kg/m3,,,,,,,,,
água,1000,Kg/m3,,água,1000,Kg/m3,,,,,,,,,
concreto,2400,kg/m3,,concreto,2500,kg/m3,,,,,,,,,
,,,+100kgm3,,,,,,,,,,,,
cálculos:,,,,cálculos:,,,,,,,,,,,
a/c=,0.54,,,a/c=, 0.36 ,,,,,,,,,,
m=, 4.77 ,,-0.18,m=, 4.77 ,,,,,,,,,,
,,,,,,,,,,,,,,,
A%=,9.36%,,-3.04,A%=,6.32%,,,,,,,,,,
,,,,,,,,,,,,,,,
C=, 380.00 ,Kg/m3,"+27,50kgm3",C=, 407.53 ,Kg/m3,,,,,,,,,
,,,,,,,,,,,,,,,
,,,,,,,,,,,,,,,
Resistência prov.=, 36.44 ,Mpa,,Resistência prov.=, 57.83 ,Mpa,,,,,,,,,
,,, +21.39Mpa,,,,,,,,,,,,
,,,,,,,,,,,,,,,
"--Para se aumentar a densidade em 100kg/m3 e se mantendo o mesmo ""m"" teremos de por cimento",,,,,,,,,,,,,,,
no lugar da água. Houve um aumento de 27kg/m3 para se aumentar a densidade em 100kg/m3. ,,,,,,,,,,,,,,,
--Com este aumento do consumo de cimento por m3 o fator a/c diminui fazendo aumentar a resistencia.,,,,,,,,,,,,,,,
"--O teor de água materiais secos A% cai, logo é necessário ter vibração muito energica",,,,,,,,,,,,,,,
"com prensagem, tipico para concreto semi-seco.",,,,,,,,,,,,,,,
--A cura para este nivel de A% deve ser muito bem controlada (A% abaixo de 7%).,,,,,,,,,,,,,,,